Technical features NT 600 |
Test points | max. 1024 in the base unit (expandable with test point units up to 5120 test points) |
Low voltage test DC |
Test voltage | max. 25 V (optional up to 250 V) |
Test current | max. 25 mA (optional up to 100 mA) |
Threshold continuity test | 1 Ohm – 1 kOhm |
Threshold short-circuit test | 20 kOhm – 1 MOhm (optional up to 100 MOhm) |
Component test | Resistors: 1 Ohm – 1 MOhm (optional up to 100 MOhm) Capacitors: 10 nF – 20 mF (optional from 10 pF) Diodes, Zener diodes, LEDs, optional: inductances, impedances, varistors (max. 1300 VDC) |
High current test DC (optional) |
Test voltage | max. 22 V |
Test current | max. 2 A (optional 10 A pulsed) |
Threshold continuity test | 0,5 Ohm – 1 kOhm |
Options | Four-wire measurement from 1 mOhm / Recognition of short time interruptions ≥ 1 μs |
High voltage test DC (optional) |
Test voltage | 40 – 1500 V |
Insulation test | 500 kOhm – 2 GOhm (optional up to 10 GOhm) |
Breakdown test | Fast recognition of voltage breakdowns (arc detection) |
Dielectric strength test AC/DC (optional) |
Test voltage / test current AC | 100 – 1060 V / max. 3 mA, safety current limited according to EN 50191 (optional max. 6 mA) |
Test voltage / test current DC | 40 – 1500 V / max. 3 mA, safety current limited according to EN 50191 (optional max. 6 mA) |
Function test (optional) |
The NT 600 can be expanded, so that the test of relays, time relays, contactors, indication lamps, function procedures etc. can be carried out automatically. Therefore stimulus cards and stimulus sources are available beside powerful software tools and editors in NT Control. |
General |
Interfaces | Interface for expansion units Extern interface with 3 opto-coupled inputs and 3 potential free outputs (expandable) Serial interfaces RS232 / USB 2.0 Network Pin number probe |
Dimensions (W x H x D, approx.) | Base unit: 450 mm x 275 mm x 395 mm Test point unit 0ZE31: 450 mm x 150 mm x 395 mm |
Scope of delivery base unit | NT 600, main cable, pin number probe, USB flash drive with NT Control and documentation in PDF format, mating connector and service connector for safety loop |